rm -rf mlog/ mkdir -p mlog/relay mlog/client Running interop tests... Relay: aiomoqt-interop-relay:latest Client: ghcr.io/englishm/moq-interop-runner-moq-test-client:latest URL: moqt://relay:4443 time="2026-10-22T00:28:38Z" level=warning msg="The \"PORT\" variable is not set. Defaulting to a blank string." time="2026-10-22T00:28:38Z" level=warning msg="The \"PORT\" variable is not set. Defaulting to a blank string." time="2026-10-22T00:28:38Z" level=warning msg="The \"PORT\" variable is not set. Defaulting to a blank string." time="2026-10-22T00:28:38Z" level=warning msg="The \"HEX\" variable is not set. Defaulting to a blank string." time="2026-10-22T00:28:38Z" level=warning msg="The \"HEX\" variable is not set. Defaulting to a blank string." Container main-test-client-1 Recreate Container main-test-client-1 Recreated Attaching to relay-1, test-client-1 Container main-relay-1 Starting Container main-relay-1 Started Container main-relay-1 Waiting relay-1 | 2026-10-22 00:28:38.516 INFO : relay: start aiomoqt 0.13.1 aiopquic 0.6.1 pid 7 relay-1 | aiomoqt ERSATZ-RELAY: an API demonstrator and conformance SUT — not a production relay (no auth, no hardening). relay-1 | 2026-10-22 00:28:38.516 INFO : Starting dual-stack MOQT server on 0.0.0.0:4443 relay-1 | ================================================================ relay-1 | EXPERIMENTAL aiomoqt interop relay. relay-1 | NOT a production relay: no auth, no scale handling. relay-1 | ================================================================ relay-1 | Listening on 0.0.0.0:4443 (dual raw QUIC + H3/WebTransport, draft-[22, 20, 18, 16, 14]) Container main-relay-1 Healthy Container main-test-client-1 Starting Container main-test-client-1 Started test-client-1 | TAP version 14 test-client-1 | # moq-test-client v0.1.15 test-client-1 | # Relay: moqt://relay:4443 test-client-1 | 1..8 test-client-1 | 2026-10-22T00:28:43.868377Z  INFO moq_native_ietf::quic: UDP socket bound bind=[::]:0 local=[::]:40958 dual_stack=true relay-1 | 2026-10-22 00:28:43.870 INFO : MOQT event: control message parsed: ClientSetup(versions=[], parameters={MAX_REQUEST_ID=100, AUTHORITY="relay:4443"})) relay-1 | 2026-10-22 00:28:43.871 INFO : MOQT send: ServerSetup(selected_version=0xff00000e, parameters={IMPLEMENTATION="aiomoqt/0.13.1", MAX_REQUEST_ID=10000}) relay-1 | 2026-10-22 00:28:43.871 INFO : MOQT session: setup complete: draft-16 (raw QUIC) test-client-1 | 2026-10-22T00:28:43.871463Z  INFO moq_test_client::scenarios: SETUP exchange completed successfully test-client-1 | ok 1 - setup-only test-client-1 | --- test-client-1 | duration_ms: 3 test-client-1 | connection_id: e5f0b9166b61652fff72c5cee96f1016 test-client-1 | ... test-client-1 | 2026-10-22T00:28:43.872006Z  INFO moq_native_ietf::quic: UDP socket bound bind=[::]:0 local=[::]:55220 dual_stack=true relay-1 | 2026-10-22 00:28:43.872 ERROR: MOQT error: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:43.872 INFO : MOQT session: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:43.872 INFO : QUIC: connection closed: code: 0 relay-1 | 2026-10-22 00:28:43.872 INFO : MOQT: closing: ConnectionTerminated (0) relay-1 | 2026-10-22 00:28:43.873 INFO : MOQT event: control message parsed: ClientSetup(versions=[], parameters={MAX_REQUEST_ID=100, AUTHORITY="relay:4443"})) relay-1 | 2026-10-22 00:28:43.873 INFO : MOQT send: ServerSetup(selected_version=0xff00000e, parameters={IMPLEMENTATION="aiomoqt/0.13.1", MAX_REQUEST_ID=10000}) relay-1 | 2026-10-22 00:28:43.873 INFO : MOQT session: setup complete: draft-16 (raw QUIC) test-client-1 | 2026-10-22T00:28:43.873481Z  INFO moq_test_client::scenarios: Sending PUBLISH_NAMESPACE for: moq-test/interop relay-1 | 2026-10-22 00:28:43.873 INFO : MOQT event: control message parsed: PublishNamespace(request_id=0, namespace=["moq-test", "interop"], parameters={})) relay-1 | 2026-10-22 00:28:43.873 INFO : relay: announce ns=(b'moq-test', b'interop') -> 1 publisher(s) relay-1 | 2026-10-22 00:28:43.873 INFO : MOQT send: RequestOk(request_id=0, parameters=None, track_properties=None) request_id: 0 namespace: (b'moq-test', b'interop') relay-1 | 2026-10-22 00:28:43.873 INFO : relay: session quic d16 from 172.18.0.3:55220 test-client-1 | 2026-10-22T00:28:45.874493Z  INFO moq_test_client::scenarios: PUBLISH_NAMESPACE succeeded (REQUEST_OK received, waiting for subscribers) test-client-1 | ok 2 - publish-namespace-only test-client-1 | --- test-client-1 | duration_ms: 2002 test-client-1 | connection_id: 7648c66829f360079f42231b4eeca90c test-client-1 | ... relay-1 | 2026-10-22 00:28:45.874 ERROR: MOQT error: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:45.875 INFO : MOQT session: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:45.875 INFO : QUIC: connection closed: code: 0 relay-1 | 2026-10-22 00:28:45.875 INFO : MOQT: closing: ConnectionTerminated (0) test-client-1 | 2026-10-22T00:28:45.875170Z  INFO moq_native_ietf::quic: UDP socket bound bind=[::]:0 local=[::]:52205 dual_stack=true relay-1 | 2026-10-22 00:28:45.876 INFO : MOQT event: control message parsed: ClientSetup(versions=[], parameters={MAX_REQUEST_ID=100, AUTHORITY="relay:4443"})) relay-1 | 2026-10-22 00:28:45.876 INFO : MOQT send: ServerSetup(selected_version=0xff00000e, parameters={IMPLEMENTATION="aiomoqt/0.13.1", MAX_REQUEST_ID=10000}) relay-1 | 2026-10-22 00:28:45.877 INFO : MOQT session: setup complete: draft-16 (raw QUIC) test-client-1 | 2026-10-22T00:28:45.877159Z  INFO moq_test_client::scenarios: Subscribing to non-existent track: nonexistent/namespace/test-track relay-1 | 2026-10-22 00:28:45.877 INFO : MOQT event: control message parsed: Subscribe(request_id=0, track_namespace=["nonexistent", "namespace"], track_name="test-track", priority=None, group_order=None, forward=None, filter_type=None, start_group=None, start_object=None, end_group=None, parameters={}, location_filter=None, track_alias=None, libquicr_compat=False)) relay-1 | 2026-10-22 00:28:45.877 INFO : relay: subscribe ns=(b'nonexistent', b'namespace') track=b'test-track' -> DOES_NOT_EXIST (not announced) relay-1 | 2026-10-22 00:28:45.877 INFO : MOQT send: RequestError(request_id=0, error_code=16, retry_interval=0, reason=track does not exist, redirect=None) test-client-1 | 2026-10-22T00:28:45.877725Z  WARN moq_test_client::scenarios: Got error but not clearly 'not found': closed, code=16. Relay may use different error text. relay-1 | 2026-10-22 00:28:45.877 ERROR: MOQT error: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:45.877 INFO : MOQT session: closing: peer closed its control stream 0 (3) test-client-1 | ok 3 - subscribe-error test-client-1 | --- test-client-1 | duration_ms: 3 test-client-1 | connection_id: 773d9860e27d08c07c00f53ab814e8d7 test-client-1 | ... test-client-1 | 2026-10-22T00:28:45.878290Z  INFO moq_native_ietf::quic: UDP socket bound bind=[::]:0 local=[::]:32902 dual_stack=true relay-1 | 2026-10-22 00:28:45.879 INFO : MOQT event: control message parsed: ClientSetup(versions=[], parameters={MAX_REQUEST_ID=100, AUTHORITY="relay:4443"})) relay-1 | 2026-10-22 00:28:45.879 INFO : MOQT send: ServerSetup(selected_version=0xff00000e, parameters={IMPLEMENTATION="aiomoqt/0.13.1", MAX_REQUEST_ID=10000}) relay-1 | 2026-10-22 00:28:45.879 INFO : MOQT session: setup complete: draft-16 (raw QUIC) test-client-1 | 2026-10-22T00:28:45.880070Z  INFO moq_native_ietf::quic: UDP socket bound bind=[::]:0 local=[::]:43201 dual_stack=true relay-1 | 2026-10-22 00:28:45.881 INFO : MOQT event: control message parsed: ClientSetup(versions=[], parameters={MAX_REQUEST_ID=100, AUTHORITY="relay:4443"})) relay-1 | 2026-10-22 00:28:45.881 INFO : MOQT send: ServerSetup(selected_version=0xff00000e, parameters={IMPLEMENTATION="aiomoqt/0.13.1", MAX_REQUEST_ID=10000}) relay-1 | 2026-10-22 00:28:45.881 INFO : MOQT session: setup complete: draft-16 (raw QUIC) test-client-1 | 2026-10-22T00:28:45.881259Z  INFO moq_test_client::scenarios: Publisher sending PUBLISH_NAMESPACE: moq-test/interop test-client-1 | 2026-10-22T00:28:45.881288Z  INFO moq_test_client::scenarios: Subscriber subscribing to track: moq-test/interop/test-track relay-1 | 2026-10-22 00:28:45.881 INFO : MOQT event: control message parsed: PublishNamespace(request_id=0, namespace=["moq-test", "interop"], parameters={})) relay-1 | 2026-10-22 00:28:45.881 INFO : relay: announce ns=(b'moq-test', b'interop') -> 1 publisher(s) relay-1 | 2026-10-22 00:28:45.881 INFO : MOQT send: RequestOk(request_id=0, parameters=None, track_properties=None) request_id: 0 namespace: (b'moq-test', b'interop') relay-1 | 2026-10-22 00:28:45.881 INFO : MOQT event: control message parsed: Subscribe(request_id=0, track_namespace=["moq-test", "interop"], track_name="test-track", priority=None, group_order=None, forward=None, filter_type=None, start_group=None, start_object=None, end_group=None, parameters={}, location_filter=None, track_alias=None, libquicr_compat=False)) relay-1 | 2026-10-22 00:28:45.881 INFO : relay: session quic d16 from 172.18.0.3:32902 relay-1 | 2026-10-22 00:28:45.882 INFO : MOQT send: Subscribe(request_id=1, track_namespace=["moq-test", "interop"], track_name="test-track", priority=None, group_order=None, forward=1, filter_type=None, start_group=0, start_object=0, end_group=0, parameters={}, location_filter=None, track_alias=None, libquicr_compat=False) relay-1 | 2026-10-22 00:28:45.882 INFO : MOQT event: control message parsed: SubscribeOk(request_id=1, track_alias=1, expires=None, group_order=1, content_exists=0, largest_group_id=None, largest_object_id=None, parameters={}, track_extensions=None)) relay-1 | 2026-10-22 00:28:45.882 INFO : Track: subscribed (direct) to (b'moq-test', b'interop')/test-track relay-1 | 2026-10-22 00:28:45.882 INFO : relay: upstream established ns=(b'moq-test', b'interop') track=test-track alias=1 relay-1 | 2026-10-22 00:28:45.882 INFO : MOQT send: SubscribeOk(request_id=0, track_alias=0, expires=0, group_order=1, content_exists=0, largest_group_id=None, largest_object_id=None, parameters={}, track_extensions={}) relay-1 | 2026-10-22 00:28:45.882 INFO : relay: subscribe ns=(b'moq-test', b'interop') track=b'test-track' -> SUBSCRIBE_OK (fanout=1) relay-1 | 2026-10-22 00:28:45.882 INFO : relay: session quic d16 from 172.18.0.3:43201 relay-1 | 2026-10-22 00:28:45.955 INFO : QUIC: connection closed: code: 0 relay-1 | 2026-10-22 00:28:45.955 INFO : MOQT: closing: ConnectionTerminated (0) test-client-1 | ok 4 - publish-namespace-subscribe test-client-1 | --- test-client-1 | duration_ms: 3004 test-client-1 | publisher_connection_id: 42a2c181bc7c80cac01d004d90177acd test-client-1 | subscriber_connection_id: eecaaec5876ed1133835a639553116ff test-client-1 | ... test-client-1 | 2026-10-22T00:28:48.882713Z  INFO moq_test_client::scenarios: Test timeout reached - subscription routing may still be in progress relay-1 | 2026-10-22 00:28:48.882 ERROR: MOQT error: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:48.883 INFO : MOQT session: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:48.883 ERROR: MOQT error: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:48.883 INFO : MOQT session: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:48.883 INFO : QUIC: connection closed: code: 0 relay-1 | 2026-10-22 00:28:48.883 INFO : MOQT: closing: ConnectionTerminated (0) relay-1 | 2026-10-22 00:28:48.883 INFO : MOQT send: SubscribeDone(request_id=0, status_code=2, stream_count=0, reason=track ended) test-client-1 | 2026-10-22T00:28:48.883408Z  INFO moq_native_ietf::quic: UDP socket bound bind=[::]:0 local=[::]:37614 dual_stack=true relay-1 | 2026-10-22 00:28:48.885 INFO : MOQT event: control message parsed: ClientSetup(versions=[], parameters={MAX_REQUEST_ID=100, AUTHORITY="relay:4443"})) relay-1 | 2026-10-22 00:28:48.886 INFO : MOQT send: ServerSetup(selected_version=0xff00000e, parameters={IMPLEMENTATION="aiomoqt/0.13.1", MAX_REQUEST_ID=10000}) relay-1 | 2026-10-22 00:28:48.886 INFO : MOQT session: setup complete: draft-16 (raw QUIC) test-client-1 | 2026-10-22T00:28:48.886233Z  INFO moq_test_client::scenarios: Subscriber subscribing BEFORE PUBLISH_NAMESPACE: moq-test/interop/test-track relay-1 | 2026-10-22 00:28:48.886 INFO : MOQT event: control message parsed: Subscribe(request_id=0, track_namespace=["moq-test", "interop"], track_name="test-track", priority=None, group_order=None, forward=None, filter_type=None, start_group=None, start_object=None, end_group=None, parameters={}, location_filter=None, track_alias=None, libquicr_compat=False)) relay-1 | 2026-10-22 00:28:48.886 INFO : relay: subscribe ns=(b'moq-test', b'interop') track=b'test-track' -> DOES_NOT_EXIST (not announced) relay-1 | 2026-10-22 00:28:48.886 INFO : MOQT send: RequestError(request_id=0, error_code=16, retry_interval=0, reason=track does not exist, redirect=None) relay-1 | 2026-10-22 00:28:48.886 INFO : QUIC: connection closed: code: 0 relay-1 | 2026-10-22 00:28:48.886 INFO : MOQT: closing: ConnectionTerminated (0) relay-1 | 2026-10-22 00:28:48.965 INFO : QUIC: connection closed: code: 0 relay-1 | 2026-10-22 00:28:48.965 INFO : MOQT: closing: ConnectionTerminated (0) test-client-1 | 2026-10-22T00:28:49.388561Z  INFO moq_native_ietf::quic: UDP socket bound bind=[::]:0 local=[::]:34358 dual_stack=true relay-1 | 2026-10-22 00:28:49.391 INFO : MOQT event: control message parsed: ClientSetup(versions=[], parameters={MAX_REQUEST_ID=100, AUTHORITY="relay:4443"})) relay-1 | 2026-10-22 00:28:49.391 INFO : MOQT send: ServerSetup(selected_version=0xff00000e, parameters={IMPLEMENTATION="aiomoqt/0.13.1", MAX_REQUEST_ID=10000}) test-client-1 | 2026-10-22T00:28:49.391988Z  INFO moq_test_client::scenarios: Publisher sending PUBLISH_NAMESPACE (after subscriber): moq-test/interop relay-1 | 2026-10-22 00:28:49.392 INFO : MOQT session: setup complete: draft-16 (raw QUIC) relay-1 | 2026-10-22 00:28:49.392 INFO : MOQT event: control message parsed: PublishNamespace(request_id=0, namespace=["moq-test", "interop"], parameters={})) relay-1 | 2026-10-22 00:28:49.392 INFO : relay: announce ns=(b'moq-test', b'interop') -> 1 publisher(s) relay-1 | 2026-10-22 00:28:49.392 INFO : MOQT send: RequestOk(request_id=0, parameters=None, track_properties=None) request_id: 0 namespace: (b'moq-test', b'interop') relay-1 | 2026-10-22 00:28:49.392 INFO : relay: session quic d16 from 172.18.0.3:34358 test-client-1 | ok 5 - subscribe-before-publish-namespace test-client-1 | --- test-client-1 | duration_ms: 3510 test-client-1 | subscriber_connection_id: cc658f4c0d64d103e6022b7a05bbc772 test-client-1 | publisher_connection_id: 5ac35e8a53d1997ee790cda527e5a616 test-client-1 | ... test-client-1 | 2026-10-22T00:28:52.393486Z  INFO moq_test_client::scenarios: Publisher PUBLISH_NAMESPACE timeout (expected) test-client-1 | 2026-10-22T00:28:52.393509Z  INFO moq_test_client::scenarios: Subscriber got error: closed, code=16 (may be expected) relay-1 | 2026-10-22 00:28:52.393 ERROR: MOQT error: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:52.393 INFO : MOQT session: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:52.394 INFO : QUIC: connection closed: code: 0 relay-1 | 2026-10-22 00:28:52.394 INFO : MOQT: closing: ConnectionTerminated (0) test-client-1 | 2026-10-22T00:28:52.394201Z  INFO moq_native_ietf::quic: UDP socket bound bind=[::]:0 local=[::]:52423 dual_stack=true relay-1 | 2026-10-22 00:28:52.397 INFO : MOQT event: control message parsed: ClientSetup(versions=[], parameters={MAX_REQUEST_ID=100, AUTHORITY="relay:4443"})) relay-1 | 2026-10-22 00:28:52.398 INFO : MOQT send: ServerSetup(selected_version=0xff00000e, parameters={IMPLEMENTATION="aiomoqt/0.13.1", MAX_REQUEST_ID=10000}) relay-1 | 2026-10-22 00:28:52.398 INFO : MOQT session: setup complete: draft-16 (raw QUIC) test-client-1 | 2026-10-22T00:28:52.398889Z  INFO moq_test_client::scenarios: Sending PUBLISH_NAMESPACE: moq-test/interop relay-1 | 2026-10-22 00:28:52.399 INFO : MOQT event: control message parsed: PublishNamespace(request_id=0, namespace=["moq-test", "interop"], parameters={})) relay-1 | 2026-10-22 00:28:52.400 INFO : relay: announce ns=(b'moq-test', b'interop') -> 1 publisher(s) relay-1 | 2026-10-22 00:28:52.400 INFO : MOQT send: RequestOk(request_id=0, parameters=None, track_properties=None) request_id: 0 namespace: (b'moq-test', b'interop') relay-1 | 2026-10-22 00:28:52.400 INFO : relay: session quic d16 from 172.18.0.3:52423 test-client-1 | 2026-10-22T00:28:54.399210Z  INFO moq_test_client::scenarios: PUBLISH_NAMESPACE active; sending PUBLISH_NAMESPACE_DONE relay-1 | 2026-10-22 00:28:54.399 ERROR: MOQT error: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:54.399 INFO : MOQT session: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:54.484 INFO : QUIC: connection closed: code: 0 relay-1 | 2026-10-22 00:28:54.484 INFO : MOQT: closing: ConnectionTerminated (0) test-client-1 | 2026-10-22T00:28:54.500243Z  INFO moq_test_client::scenarios: PUBLISH_NAMESPACE_DONE sent successfully test-client-1 | ok 6 - publish-namespace-done test-client-1 | --- test-client-1 | duration_ms: 2106 test-client-1 | connection_id: 02815698afb8f6d0e5d1242372a2bc80 test-client-1 | ... test-client-1 | 2026-10-22T00:28:54.500955Z  INFO moq_native_ietf::quic: UDP socket bound bind=[::]:0 local=[::]:46218 dual_stack=true relay-1 | 2026-10-22 00:28:54.502 INFO : MOQT event: control message parsed: ClientSetup(versions=[], parameters={MAX_REQUEST_ID=100, AUTHORITY="relay:4443"})) relay-1 | 2026-10-22 00:28:54.502 INFO : MOQT send: ServerSetup(selected_version=0xff00000e, parameters={IMPLEMENTATION="aiomoqt/0.13.1", MAX_REQUEST_ID=10000}) relay-1 | 2026-10-22 00:28:54.502 INFO : MOQT session: setup complete: draft-16 (raw QUIC) test-client-1 | 2026-10-22T00:28:54.503025Z  INFO moq_test_client::scenarios: Publisher sending direct PUBLISH namespace=/moq-test/publish track="published-track" relay-1 | 2026-10-22 00:28:54.503 INFO : MOQT event: control message parsed: Publish(request_id=0, track_namespace=["moq-test", "publish"], track_name="published-track", track_alias=0, group_order=1, content_exists=0, largest_group_id=None, largest_object_id=None, forward=None, parameters={}, track_extensions=None)) relay-1 | 2026-10-22 00:28:54.503 INFO : relay: publish ns=(b'moq-test', b'publish') track=b'published-track' alias=0 relay-1 | 2026-10-22 00:28:54.503 INFO : MOQT send: PublishOk(request_id=0, forward=0, priority=128, group_order=1, filter_type=2, start_group=None, start_object=None, end_group=None, parameters={}, expires=None, location_filter=None) relay-1 | 2026-10-22 00:28:54.503 INFO : relay: PUBLISH_OK forward=0 alias=0 — parked until a subscriber forwards relay-1 | 2026-10-22 00:28:54.503 INFO : relay: session quic d16 from 172.18.0.3:46218 test-client-1 | 2026-10-22T00:28:54.503712Z  INFO moq_test_client::scenarios: PUBLISH accepted namespace=/moq-test/publish track="published-track" test-client-1 | 2026-10-22T00:28:54.503743Z  INFO moq_test_client::scenarios: PUBLISH completed namespace=/moq-test/publish track="published-track" test-client-1 | ok 7 - publish-track-only relay-1 | 2026-10-22 00:28:54.503 ERROR: MOQT error: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:54.503 INFO : MOQT session: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:54.504 INFO : QUIC: connection closed: code: 0 relay-1 | 2026-10-22 00:28:54.504 INFO : MOQT: closing: ConnectionTerminated (0) test-client-1 | --- test-client-1 | duration_ms: 3 test-client-1 | connection_id: 8e9dcc32409aea0f201e489ef23976d8 test-client-1 | ... test-client-1 | 2026-10-22T00:28:54.504375Z  INFO moq_native_ietf::quic: UDP socket bound bind=[::]:0 local=[::]:59902 dual_stack=true relay-1 | 2026-10-22 00:28:54.505 INFO : MOQT event: control message parsed: ClientSetup(versions=[], parameters={MAX_REQUEST_ID=100, AUTHORITY="relay:4443"})) relay-1 | 2026-10-22 00:28:54.505 INFO : MOQT send: ServerSetup(selected_version=0xff00000e, parameters={IMPLEMENTATION="aiomoqt/0.13.1", MAX_REQUEST_ID=10000}) relay-1 | 2026-10-22 00:28:54.505 INFO : MOQT session: setup complete: draft-16 (raw QUIC) test-client-1 | 2026-10-22T00:28:54.506100Z  INFO moq_native_ietf::quic: UDP socket bound bind=[::]:0 local=[::]:38147 dual_stack=true relay-1 | 2026-10-22 00:28:54.508 INFO : MOQT event: control message parsed: ClientSetup(versions=[], parameters={MAX_REQUEST_ID=100, AUTHORITY="relay:4443"})) test-client-1 | 2026-10-22T00:28:54.508268Z  INFO moq_test_client::scenarios: Publisher sending direct PUBLISH before subscriber subscribes namespace=/moq-test/publish track="published-track" relay-1 | 2026-10-22 00:28:54.508 INFO : MOQT send: ServerSetup(selected_version=0xff00000e, parameters={IMPLEMENTATION="aiomoqt/0.13.1", MAX_REQUEST_ID=10000}) relay-1 | 2026-10-22 00:28:54.508 INFO : MOQT session: setup complete: draft-16 (raw QUIC) relay-1 | 2026-10-22 00:28:54.508 INFO : MOQT event: control message parsed: Publish(request_id=0, track_namespace=["moq-test", "publish"], track_name="published-track", track_alias=0, group_order=1, content_exists=0, largest_group_id=None, largest_object_id=None, forward=None, parameters={}, track_extensions=None)) relay-1 | 2026-10-22 00:28:54.508 INFO : relay: publish ns=(b'moq-test', b'publish') track=b'published-track' alias=0 relay-1 | 2026-10-22 00:28:54.508 INFO : MOQT send: PublishOk(request_id=0, forward=0, priority=128, group_order=1, filter_type=2, start_group=None, start_object=None, end_group=None, parameters={}, expires=None, location_filter=None) test-client-1 | 2026-10-22T00:28:54.508763Z  INFO moq_test_client::scenarios: PUBLISH accepted; starting subscriber namespace=/moq-test/publish track="published-track" relay-1 | 2026-10-22 00:28:54.508 INFO : relay: PUBLISH_OK forward=0 alias=0 — parked until a subscriber forwards relay-1 | 2026-10-22 00:28:54.508 INFO : relay: session quic d16 from 172.18.0.3:59902 relay-1 | 2026-10-22 00:28:54.508 INFO : MOQT event: control message parsed: Subscribe(request_id=0, track_namespace=["moq-test", "publish"], track_name="published-track", priority=None, group_order=None, forward=None, filter_type=None, start_group=None, start_object=None, end_group=None, parameters={}, location_filter=None, track_alias=None, libquicr_compat=False)) relay-1 | 2026-10-22 00:28:54.509 INFO : MOQT send: SubscribeOk(request_id=0, track_alias=0, expires=0, group_order=1, content_exists=0, largest_group_id=None, largest_object_id=None, parameters={}, track_extensions={}) relay-1 | 2026-10-22 00:28:54.509 INFO : MOQT send: RequestUpdate(request_id=1, existing_request_id=0, parameters={FORWARD=1}) relay-1 | 2026-10-22 00:28:54.509 INFO : relay: REQUEST_UPDATE forward=1 alias=0 relay-1 | 2026-10-22 00:28:54.509 INFO : relay: subscribe ns=(b'moq-test', b'publish') track=b'published-track' -> SUBSCRIBE_OK (published track, fanout=1) relay-1 | 2026-10-22 00:28:54.509 INFO : relay: session quic d16 from 172.18.0.3:38147 relay-1 | 2026-10-22 00:28:54.509 INFO : MOQT event: control message parsed: RequestError(request_id=1, error_code=3, retry_interval=0, reason=not supported, redirect=None)) relay-1 | 2026-10-22 00:28:54.609 INFO : MOQT event: control message parsed: SubscribeDone(request_id=0, status_code=2, stream_count=0, reason=publish ended)) relay-1 | 2026-10-22 00:28:54.610 INFO : relay: publisher PUBLISH_DONE ((b'moq-test', b'publish'), b'published-track') status=2 streams=0 -> 1 subscriber(s), objects in=0 out=0 relay-1 | 2026-10-22 00:28:54.610 INFO : MOQT send: SubscribeDone(request_id=0, status_code=2, stream_count=0, reason=publish ended) test-client-1 | not ok 8 - publish-track-subscribe test-client-1 | --- test-client-1 | duration_ms: 106 test-client-1 | message: "subscriber track mode failed: done" test-client-1 | ... relay-1 | 2026-10-22 00:28:54.610 ERROR: MOQT error: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:54.610 INFO : MOQT session: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:54.610 ERROR: MOQT error: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:54.610 INFO : MOQT session: closing: peer closed its control stream 0 (3) relay-1 | 2026-10-22 00:28:54.610 INFO : QUIC: connection closed: code: 0 relay-1 | 2026-10-22 00:28:54.610 INFO : MOQT: closing: ConnectionTerminated (0) relay-1 | 2026-10-22 00:28:54.610 INFO : QUIC: connection closed: code: 0 relay-1 | 2026-10-22 00:28:54.610 INFO : MOQT: closing: ConnectionTerminated (0) test-client-1 exited with code 1 Compose Stopping Aborting on container exit... Container main-test-client-1 Stopping Container main-test-client-1 Stopped Container main-relay-1 Stopping Container main-relay-1 Stopped relay-1 exited with code 143 make: *** [Makefile:86: test] Error 1